"Manics node is not installed" in Kyocera: what to do

Anonim

Method 1: Cartridge Replacement

In most cases, the source of the problem is not the progress itself (it is also developer unit), and the cartridge with a toner. The fact is that printers and MFPs of this Japanese company interact very poorly with non-original consumables, because in order to save them, the sensor for the presence of toner is not established. The system cannot assume the amount of the remaining powder and knocks the error. On some series (known about 1035 and 2035), this may happen with the original containers for thermocheries, but which for the purpose of economy rewritten. For a 100% effective solution to the problem, you need to install a new container from the manufacturer.

Method 2: Refill cartridge

For those who are not suitable for those, you can try to refuel the printing element with new inks - for most models of printers, MFP and copies of this manufacturer, this operation can be performed independently.

  1. In the Kyocera cartridges, the hole for refilling toner is closed with a plug - it can be opened if used, for example, scolding.

    In older models (up to 2018 release), the cork is often intense. It also gives to an autopsy, but with the help of a knife, blades for a razor machine or technical scalpel, however, when closing, the container will need to be sealing, which is not always possible at home. The optimal option in such a situation will attribute this cartridge to those skilled in the art, where you will receive a component ready for installation.

  2. Next, it is necessary to stamp output openings of the cartridge (closed by foam-plane) with a tape or tape - it is necessary to do so that the paint does not fall out.
  3. If there are remnants of the old toner in the tank, it is necessary to get rid of them: carefully pour out into a dense cellophane or paper bag, and if possible, blow the compressor. Of course, this procedure should be performed either on the street or in the technical room.
  4. Next, fall asleep the new toner through the main hole. The quantity depends on the specific model of the device: For some options, it will be enough about 100-150 g, whereas for others it is necessary to refuel at least 300 g. The correct weight can be found by using the search on the Internet on request * the device model * refueling.

    After that, close the cork and make sure that it sits tightly and does not give up.

  5. Now it is necessary to establish a new toner chip. In some embodiments, it is inserted into the compartment on plastic strings - it is enough to pry it clearly and extract the old one, then also carefully install a new one.

    In other chip, a chip is sealed in flexible plastic - it must be rejected to replace such an element from the body (if the composition does not break off, use the non-aggressive solvent like isopropyl alcohol), degrease the landing site and glue a new one.

  6. Remove the glued isolate or tape on the outlet of the cartridge, then set it back to the target device.
  7. The cartridge will be charged and ready for operation, and the error of the manifest node should no longer appear.

Method 3: Replacement of the manifestation node

In some cases, the error under consideration is still associated with the manifestation apparatus, which indicates its appearance with an obviously good and refilled original cartridge. For diagnostics, do the following:

  1. First of all, try to remove the problem block and check its condition. The fact is that it is often an error arises due to problems with the node recognition by the main device, and most often the fault of that contamination on the sensor. If traces of dirt, paint or dust are visually noticeable, be sure to wipe, set it back and check the error.
  2. Also, inspect the design slot of the manifestation assembly - for normal performance there should be no dust or contamination in it. If such are discovered, remove them.
  3. If the previous steps have not led to anything, the only removal method is to visit the repair shop: it is usually possible to fix similar problems to those skilled in the breed.

In general, the error of the manifest node is less related directly to it than with a cartridge.

Read more